检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Mitsuki Tomita Takeshi Ogura Akitoshi Hakoda Saori Ueno Atsushi Okuda Nobu Nishioka Yoshitaro Yamamoto Hiroki Nishikawa
机构地区:[1]2nd Department of Internal Medicine,Osaka Medical and Pharmaceutical University,Osaka,Japan [2]Endoscopy Center,Osaka Medical and Pharmaceutical University,Osaka,Japan
出 处:《Hepatobiliary & Pancreatic Diseases International》2024年第2期181-185,共5页国际肝胆胰疾病杂志(英文版)
摘 要:Background:To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy(EUS-HGS),intra-scope channel release technique is important,but is unfamiliar to non-expert hands.The self-expandable metal stent(SEMS)is an additional factor to prevent stent migration.However,no compara-tive studies of laser-cut-type and braided-type during EUS-HGS have been reported.The aim of this study was to compare the distance between the intrahepatic bile duct and stomach wall after EUS-HGS among laser-cut-type and braided-type SEMS.Methods:To evaluate stent anchoring function,we measured the distance between the hepatic parenchyma and stomach wall before EUS-HGS,one day after EUS-HGS,and 7 days after EUS-HGS.Also,propensity score matching was performed to create a propensity score for using laser-cut-type group and braided-type group.Results:A total of 142 patients were enrolled in this study.Among them,24 patients underwent EUS-HGS using a laser-cut-type SEMS,and 118 patients underwent EUS-HGS using a braided-type SEMS.EUS-HGS using the laser-cut-type SEMS was mainly performed by non-expert endoscopists(n=21);EUS-HGS using braided-type SEMS was mainly performed by expert endoscopists(n=98).The distance after 1 day was significantly shorter in the laser-cut-type group than that in the braided-type group[2.00(1.70-3.75)vs.6.90(3.72-11.70)mm,P<0.001].In addition,this distance remained significantly shorter in the laser-cut-type group after 7 days.Although these results were similar after propensity score matching analysis,the distance between hepatic parenchyma and stomach after 7 days was increased by 4 mm compared with the distance after 1 day in the braided-type group.On the other hand,in the laser-cut-type group,the distance after 1 day and 7 days was almost the same.Conclusions:EUS-HGS using a laser-cut-type SEMS may be safe to prevent stent migration,even in non-expert hands.
关 键 词:Endoscopic ultrasound-guided hepaticogastrostomy Endoscopic ultrasound-guided biliary drainage Endoscopic retrograde CHOLANGIOPANCREATOGRAPHY
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.63