检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:游衍春 杨明浩 张效 刘津津 范校周 孙嗣国 刘禧 You Yanchun;Yang Minghao;Zhang Xiao;Liu Jinjin;Fan Xiaozhou;Sun Siguo;Liu Xi(Department of Ultrasound,Air Force Medical Center,Air Force Medical University,Beijing 100142,China;China Medical University,Shenyang 110122,China;Acceleration Physiology Laboratory,Air Force Medical Center,Air Force Medical University,Beijing 100142,China;Department of Orthopedics,Air Force Medical Center,Air Force Medical University,Beijing 100142,China)
机构地区:[1]空军军医大学空军特色医学中心超声诊断科,北京100142 [2]中国医科大学,沈阳110122 [3]空军军医大学空军特色医学中心加速度生理研究室,北京100142 [4]空军军医大学空军特色医学中心骨科,北京100142
出 处:《中华超声影像学杂志》2024年第3期242-246,共5页Chinese Journal of Ultrasonography
基 金:空军军医大学效能提升项目(2019ZTB05);空军特色医学中心科技助推揭榜挂帅项目(2022ZTJB01);空军装备综合研究项目(KJ20211030248)。
摘 要:目的应用经颅多普勒超声联合逐波血压监测探讨飞行员急性正加速度(+Gz)暴露后脑血流动态调节能力的变化。方法前瞻性纳入2022年6-10月于空军军医大学空军特色医学中心接受离心机+8Gz高载荷耐力测试的男性飞行员26例。于试验前静息状态和离心后5 min内分别监测血压、心率,并使用经颅多普勒超声联合无创连续血压监测仪监测双侧大脑中动脉血流速度和无创逐波血压,应用传递函数分析计算得出双侧0.02~0.50 Hz各频段内的脑血流动态调节参数,并计算相位差、增益和一致性。比较静息状态与离心后上述参数的差异。结果与静息状态相比,26例飞行员在+8Gz急性高载荷暴露后收缩压、舒张压、心率显著升高(均P<0.001);在超低频段(0.02~0.07 Hz)相位差显著升高,增益显著降低(均P<0.05);而在低频段(0.07~0.20 Hz)和高频段(0.20~0.50 Hz)静息状态与离心后相位差和增益差异无统计学意义(均P>0.05)。结论经颅多普勒超声联合逐波血压监测可用于检测高载荷急性+Gz暴露后脑血流动态调节变化。传递函数分析超低频段参数适用于此类评估。Objective To explore the changes of dynamic cerebral autoregulation ability in pilots exposed to acute positive acceleration(+Gz)by transcranial Doppler combined with beat-to-beat blood pressure.Methods A total of 26 pilots enrolled in the+8Gz manned centrifuge trial at the Air Force Medical Center,Air Force Medical University from June to October 2022 were prospectively included.Blood pressure and heart rate were monitored in the resting state before the trial and within 5 min after centrifugation.Transcranial Doppler combined with noninvasive continuous beat-to-beat blood pressure monitor were used to detect bilateral middle cerebral artery blood flow velocity and beat-to-beat pulse pressure respectively.The transfer function analysis was applied to derive the parameters of cerebral blood flow autoregulation in each frequency band from 0.02 to 0.50 Hz,and the phase,gain and coherence were calculated.The above parameters were compared between resting state and after acute+8Gz positive acceleration exposure.Results Compared with the resting state,in all of the 26 pilots after acute+8Gz positive acceleration exposure,the systolic and diastolic blood pressure and heart rate increased significantly(P<0.001),the phase significantly increased and the gain significantly decreased in the ultra-low frequency band(0.02-0.07 Hz)(P<0.05);whereas there were no statistical differences of gain and phase in the low frequency band(0.07-0.20 Hz)and the high frequency band(0.20-0.50 Hz)(all P>0.05).Conclusions Transcranial Doppler combined with beat-to-beat pulse pressure can be used for the assessment of changes in immediate dynamic cerebral autoregulation after acute+Gz exposure,and transfer function analysis of ultra-low frequency band parameters is suitable for this type of evaluation.
关 键 词:经颅多普勒 脑血流动态调节 传递函数分析 载人离心机 正加速度
分 类 号:R85[医药卫生—航空、航天与航海医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222