一种能自净的变电站电抗器室环境治理方法  

Environment Management Method for Substation Reactor Room Enabling Automated Cleaning

在线阅读下载全文

作  者:雷剧璋 冯镇生 LEI Juzhang;FENG Zhensheng(Foshan Power Supply Bureau,Guangdong Power Grid Corporation,Foshan 528000,China)

机构地区:[1]广东电网有限责任公司佛山供电局,广东佛山528000

出  处:《电工技术》2024年第6期191-193,共3页Electric Engineering

摘  要:在变电站中,220 kV主变压器变低串联电抗器长期运行会产生大量热量,而长期积聚的灰尘会对设备散热和绝缘性能造成影响。提出了一种电抗器室自动清灰系统,旨在解决这些问题。探讨了该系统的设计原理、工作机制和优化方法,并通过实验和实际应用验证了其效果。In a substation,long-term operation of 220 kV main transformer and its connected shunt reactor generates a significant amount of heat,while the accumulation of dust over time can affect the equipment's heat dissipation and insulation performance.This paper proposes an automatic dust removal system for the reactor chamber to address these issues.The design principles,operational mechanisms,and optimization methods of this system are be discussed,and its effectiveness is validated through experiments and practical applications.

关 键 词:变电站 串联电抗器 散热 除尘装置 

分 类 号:TM411[电气工程—电器]

 