风光储参与电网预防-紧急控制策略研究  被引量:3

RESEARCH ON POWER GRID PREVENTION-EMERGENCY CONTROL STRATEGY WITH WIND AND SOLAR STORAGE PARTICIPATION

在线阅读下载全文

作  者:万庆祝[1] 袁润娇 李伊梦 李治萱 Wan Qingzhu;Yuan Runjiao;Li Yimeng;Li Zhixuan(School of Electric and Control Engineering,North China University of Technology,Beijing 100144,China)

机构地区:[1]北方工业大学电气与控制工程学院,北京100144

出  处:《太阳能学报》2024年第4期404-415,共12页Acta Energiae Solaris Sinica

基  金:配用电大数据智能运维关键技术研究(110052972027/067);北京市电力节能协同创新(2011)研究项目(PXM2018_014212_000015_4_4)。

摘  要:基于风光储有功功率连续平滑调节能力,提出一种风光储协同切负荷优化的电网预防-紧急控制策略。首先,分析风光储参与电网预防-紧急控制原理,给出风光储参与电网预防-紧急控制策略。在故障发生前通过削减风光出力预留有功备用容量,通过调整发电机机组出力、储能充放电状态平抑风光出力改变引起的系统功率波动;在故障发生后,优先考虑风光预留有功备用量填补系统功率不平衡量,若风光预留有功备用量不足,则采取切负荷措施进行紧急控制。然后,综合考虑风光有功备用成本、预防、紧急控制措施成本,分别建立风光储参与电网预防、紧急控制模型,采用Matlab/CPLEX求解模型。最后在改进IEEE 39节点系统进行仿真验证本文所提控制策略的有效性。Based on the continuous and smooth adjustment capability of the active power of the wind-solar storage,this paper proposes a power grid prevention-emergency control strategy based on wind-solar storage and load shedding optimization.Firstly,the principle of the wind-solar storage participation in grid prevention-emergency control is analyzed and the control strategy is given.Before the fault occurring,the active reserve capacity is reserved by reducing the wind-solar output,and the system power fluctuation caused by the change of wind-solar output is smoothed by adjusting the generator unit output and storage charging or discharging status.After the fault occurring,the wind-solar reserved active backup is given priority to fill the system power imbalance,if it is not enough,then taking load shedding measures for emergency control.Finally,considering the cost of wind-solar reserved active backup,the cost of prevention and emergency control measures,the prevention and emergency control models for the participation of wind-solar storage in the power grid are established,respectively.Solving the models with CPLEX solver.The final example analysis of the improved IEEE 39 node verifies the effectiveness of the proposed control architecture and control method.

关 键 词:可再生能源 优化 成本 风光有功备用 预防-紧急控制策略 

分 类 号:TM711[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象