检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:白雪华 孟佩俊[1] 李淑荣[1] 刘燕茹[2] 罗利霞 BAI Xue-hua;MENG Pei-jun;LI Shu-rong;LIU Yan-ru;LUO Li-xia(Public Health School,Baotou Medical College,Inner Mongolia University of Science&Technology,Baotou 014040,China;School of Medical Technology and Anesthesia,Baotou Medical College,Inner Mongolia University of Science and Technology,Baotou 014040,China)
机构地区:[1]包头医学院公共卫生学院,内蒙古包头014040 [2]包头医学院医学技术与麻醉学院,内蒙古包头014040
出 处:《现代化工》2024年第5期251-256,共6页Modern Chemical Industry
基 金:包头医学院大学生“花蕾计划”项目(110-2023300729);内蒙古自治区教育教学研究“十四五”规划项目(NGJGH202203)。
摘 要:先通过滴涂法制备纳米氧化铈-石墨烯(CeO_(2)-Gr)复合物修饰玻碳电极(GCE),再在含氯金酸(HAuCl_(4))的缓冲溶液中,采用循环伏安法将Au(Ⅲ)还原到CeO_(2)-Gr表面,从而制得AuNPs/CeO_(2)/Gr/GCE。采用电化学阻抗谱法(EIS)对修饰电极进行电化学特性表征。研究了AuNPs/CeO_(2)/Gr/GCE快速、准确测定水环境中As(Ⅲ),采用差分脉冲溶出伏安法,探讨了氧化铈与石墨烯质量比、金纳米粒子沉积圈数、沉积时间和沉积电位及干扰离子等对测定结果的影响,并确定检测As(Ⅲ)的优化实验条件。在最优条件下,该电化学传感器对As(Ⅲ)具有良好的电流响应,其溶出伏安峰电流与As(Ⅲ)浓度的线性范围为13.35~387.15μmol/L,检出限为4.74μmol/L。在不同干扰离子存在的情况下,传感器对As(Ⅲ)的选择性较好。为了评估传感器的实际应用能力,以实验室自来水为样本进行As(Ⅲ)加标检测,加标回收率为90.5%~99.2%,表明该电化学传感器具有监测As(Ⅲ)的应用潜力。Nano cerium oxide-graphene composite modified glassy carbon electrode(CeO_(2)-Gr/GCE)is prepared through a drop coating method.Furthermore,AuNPs/CeO_(2)-Gr/GCE is prepared through reducing Au(Ⅲ)onto the surface of CeO_(2)-Gr by cyclic voltammetry method in buffer solution containing chloroauric acid(HAuCl_(4)).The modified electrode is characterized by means of electrochemical impedance spectroscopy(EIS).A fast and accurate differential pulse stripping voltammetry method(DPSV)based on AuNPs/CeO_(2)-Gr/GCE is developed for determining As(Ⅲ)in the aqueous environment.Some influencing factors such as the mass ratio of graphene to cerium oxide,the circle number,time and potential of gold nanoparticle sedimentation,and interference ions are studied,and the optimal experimental conditions for detecting are determined.Under the optimal experimental conditions,As(Ⅲ)shows a good current response on this modified electrode.The electrode exhibits good linearity and reproducibility for As(Ⅲ)concentration in the range of 13.35-387.15μmol·L^(-1),with a detection limit of 4.74μmol·L^(-1).It is indicated by anti-interference experiment result that this modified electrode exhibits good selectivity for As(Ⅲ).As the modified electrode is served for the determination of As(Ⅲ)in laboratory tap water samples,the spiked recovery ranges from 90.5%to 100.1%,indicating a potential in monitoring As(Ⅲ).
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.154.109