汽动给水泵机械密封水温度异常升高分析与对策  

Analysis and Countermeasures on Abnormal Temperature Rise of Mechanical Sealed Water in Turbine-driven Feed Pumps

在线阅读下载全文

作  者:潘阳 PAN Yang(Anhui Hefei United Power Generation Co.,Ltd.,Hefei 230617)

机构地区:[1]安徽省合肥联合发电有限公司,安徽合肥230617

出  处:《电力安全技术》2024年第4期70-73,共4页Electric Safety Technology

摘  要:在发生火力发电厂汽动给水泵机械密封系统故障时,很可能会造成汽动给水泵跳闸,危及机组安全运行。基于现场一起汽动给水泵机械密封水温度异常升高现象,分析排查故障原因,提出异常处理方法、整改措施及建议,以期为汽动给水泵机械密封水温度异常升高的处理提供参考。Once the mechanical seal system of feed pumps fails in a thermal power plant,it is likely to cause a trip of turbine-driven feed pumps,endangering the safe operation of the units.Based on the abnormal temperature rise of mechanical seal water system in a turbine-driven feed pump of the plant,the failure causes are analyzed,based on which the anomaly handling methods,corrective measures and suggestions are put forward so as to offer reference for the treatment of such an abnormal temperature rise of mechanical sealed water in turbine-driven feed pumps.

关 键 词:汽动给水泵 机械密封水 冷却器 泄漏 

分 类 号:TM621.3[电气工程—电力系统及自动化]

 