基于原子荧光光度法对水中砷进行精密度偏性试验  

Precision Bias Test for Arsenic in Water Based on Atomic Fluorescence Spectrophotometry

在线阅读下载全文

作  者:张婧 Zhang Jing(Shanxi Dibao Energy Co.,Ltd.,Taiyuan Shanxi 030045,China)

机构地区:[1]山西地宝能源有限公司,山西太原030045

出  处:《山西化工》2024年第4期70-72,共3页Shanxi Chemical Industry

摘  要:在当前的水污染监测和防治过程中,砷的质量浓度是污染检测中的关键指标,可为水污染处理提供数据参考,常用原子荧光光度法进行检测。为保障该检测方法的应用具有可靠性,有必要基于原子荧光光度法对水中砷进行精密度偏性试验,确保水中砷元素的检测工作具有科学性、合理性。基于此,概述了精密度偏性试验,分析了试验准备情况,讨论试验落实和数据应用,以期合理应用该检测方法,提高水中砷的检测效果。In the current process of water pollution monitoring and prevention,the mass concentration of arsenic is a key indicator in pollution detection,which can provide data reference for water pollution treatment.Atomic fluorescence spectrophotometry is commonly used for detection.To ensure the reliability of the application of this detection method,it is necessary to conduct precision bias tests on arsenic in water based on atomic fluorescence spectrophotometry to ensure that the detection of arsenic in water is scientific and reasonable.Based on this,an overview of precision bias testing was provided,and the preparation for the experiment was analyzed.The implementation of the experiment and the application of data were discussed in order to apply the detection method reasonably and improve the detection effect of arsenic in water.

关 键 词:原子荧光光度法 水中砷 精密度偏性实验 

分 类 号:X832[环境科学与工程—环境工程]

 