Dual degree branched type-2 fuzzy controller optimized with a hybrid algorithm for frequency regulation in a triple-area power system integrated with renewable sources  被引量:2

在线阅读下载全文

作  者:Nisha Kumari Pulakraj Aryan G.Lloyds Raja Yogendra Arya 

机构地区:[1]Department of Electrical Engineering,Indian Institute of Technology(Indian School of Mines),Dhanbad,India [2]Department of Electrical Engineering,National Institute of Technology,Patna,India [3]Department of Electrical Engineering,J.C.Bose University of Science and Technology,YMCA,Faridabad,Haryana,India

出  处:《Protection and Control of Modern Power Systems》2023年第3期196-224,共29页现代电力系统保护与控制(英文)

摘  要:The uncertainties associated with multi-area power systems comprising both thermal and distributed renewable generation(DRG)sources such as solar and wind necessitate the use of an efficient load frequency control(LFC)technique.Therefore,a hybrid version of two metaheuristic algorithms(arithmetic optimization and African vulture’s optimization algorithm)is developed.It is called the‘arithmetic optimized African vulture’s optimization algorithm(AOAVOA)’.This algorithm is used to tune a novel type-2 fuzzy-based proportional–derivative branched with dual degree-of-freedom proportional–integral–derivative controller for the LFC of a three-area hybrid deregulated power system.Thermal,electric vehicle(EV),and DRG sources(including a solar panel and a wind turbine system)are con-nected in area-1.Area-2 involves thermal and gas-generating units(GUs),while thermal and geothermal units are linked in area-3.Practical restrictions such as thermo-boiler dynamics,thermal-governor dead-band,and genera-tion rate constraints are also considered.The proposed LFC method is compared to other controllers and optimizers to demonstrate its superiority in rejecting step and random load disturbances.By functioning as energy storage ele-ments,EVs and DRG units can enhance dynamic responses during peak demand.As a result,the effect of the afore-mentioned units on dynamic reactions is also investigated.To validate its effectiveness,the closed-loop system is subjected to robust stability analysis and is compared to various existing control schemes from the literature.It is determined that the suggested AOAVOA improves fitness by 40.20%over the arithmetic optimizer(AO),while fre-quency regulation is improved by 4.55%over an AO-tuned type-2 fuzzy-based branched controller.

关 键 词:Load frequency control Distributed generation Energy storage devices Type-2 fuzzy proportional-derivative branched with dual-degree-of-freedom proportional-integral-derivative controller Hybrid arithmetic optimized African vulture’s optimization algorithm 

分 类 号:TP273[自动化与计算机技术—检测技术与自动化装置]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象