医药产业园区废水处理工程实例  

An example of wastewater treatment project in pharmaceutical industrial park

在线阅读下载全文

作  者:孙国栋 SUN Guodong(Shandong Hi-speed Green Technology Development Co.,Ltd.,Ji′nan 250014,China)

机构地区:[1]山东高速绿色技术发展有限公司,济南250014

出  处:《工业用水与废水》2024年第2期86-90,共5页Industrial Water & Wastewater

摘  要:针对山东某医药产业园区生产废水高COD、高氨氮、高盐分和可生化性差等特点,设计采用蒸氨-MVR蒸发结晶-臭氧催化氧化-A^(2)/O-深度处理工艺,处理水量为500 m^(3)/d。工程实践表明,该工艺对COD、氨氮、总氮、总磷和SS的去除率分别达到了97.1%、89.9%、85.9%、93.5%和96.3%,相应出水水质分别为358、27、52、0.62和40 mg/L,出水水质满足GB/T 31962—2015《污水排入城镇下水道水质标准》中的A级排放标准。According to the characteristics of the wastewater in a pharmaceutical industrial park in Shandong province such as:high COD and ammonia nitrogen concentrations,high salinity and poor biodegradability,a combined process of ammonia distillation-MVR evaporative crystallization-catalytic ozonation-A^(2)/O-advanced treatment was adopted,and the design treated water volume was 500 m^(3)/d.The engineering practice showed that,the removal rates of COD,ammonia nitrogen,total nitrogen,total phosphorus and SS by the said process reached 97.1%、89.9%、85.9%、93.5%and 96.3%respectively,the effluent water quality met the requirement of A-level discharge standard of GB/T 31962—2015 Wastewater quality standards for discharge to municipal sewers.

关 键 词:医药废水 混凝沉淀 蒸氨 MVR蒸发结晶 臭氧氧化 A2/O工艺 

分 类 号:X703.1[环境科学与工程—环境工程] X505

 