检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:何金妹 HE Jin-mei(Guangdong Masscreation Testing Co.,Ltd.,Guangdong Zhaoqing 526000,China)
出 处:《广州化工》2024年第1期126-128,共3页GuangZhou Chemical Industry
摘 要:依据GB/T 7466-87《水质总铬的测定》的标准方法原理,依次从标液稀释、标准曲线拟合、实验员的取样误差和样品前处理等过程中分析和评定了废水中总铬含量的不确定度。本次废水总铬测量结果为:(0.050±0.002)mg/L,k=2。由不确定度的分析结果可知,标液稀释和仪器误差对不确定度的影响最大,是不确定度测定的主要来源。本次不确定度评定的实验为提高实际工作的准确性提供引导作用。Based on the principle of GB/T 7466-87 Water quality,determination of Chromium,the uncertainty of Chromium content was analyzed and evaluated from the dilution process of standerd solution,the fitting of standerd curve,the sampling error of operater and the pretreatment of samples,and the effective methods were put forward.The result of Chromium was(0.050±0.002)mg/L,k=2.Seen from the analysis results of uncertainty,the dilution of standard solution and instrument error had the greatest impact on the uncertainty and were also the main sources of uncertainty measurement.The uncertainty evalution method had certain guiding significance for improving the accuracy of practical work.