影响横管初冷器余热水温度的因素及解决措施  

Factors influencing temperature of waste heat water in cross-tube primary coolers and the solutions

在线阅读下载全文

作  者:周庆鑫 高占先 吕明 郑占全 Zhou Qingxin;Gao Zhanxian;Lv Ming;Zheng Zhanquan(Ansteel Chemical Technology Co.,Ltd.,Anshan 114021,China)

机构地区:[1]鞍钢化学科技有限公司,鞍山114021

出  处:《燃料与化工》2024年第3期52-55,共4页Fuel & Chemical Processes

摘  要:以鞍钢化学科技有限公司回收作业区的初冷器为研究对象,探究了初冷器内漏、初冷器清扫方式和余热水槽温度等因素对余热水温度的影响,对每种影响因素提出针对性的解决措施。实践表明,余热水平均送水温度由48.4℃提高至54.2℃。This study,centered on the cross-tube primary cooler in the by-product plant of Ansteel Chemical Technology Co.,Ltd.,investigates the effects of various factors on the temperature of waste heat water,including internal leakage within the primary cooler,cleaning methods,and the temperature of the waste heat water tank.For each factor,specific solutions are proposed.The result in application shows a significant increase in the average temperature of the feeding waste heat water,rising from 48.4℃to 54.2℃.

关 键 词:初冷器 余热水 温度 

分 类 号:TQ522.5[化学工程—煤化学工程]

 