检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Jiawei Zhuang Genyang Chen Rumeng Yang Kun Han Dongdong Tian Yongfa Diao Henggen Shen
机构地区:[1]School of Urban Construction,Changzhou University,Changzhou,213164,China [2]School of Petroleum and Natural Gas Engineering,School of Energy,Changzhou University,Changzhou,213164,China [3]College of Environmental Science and Engineering,Donghua University,Shanghai,201620,China [4]School of Architecture and Urban Planning,Nanjing University,Nanjing,210093,China
出 处:《Building Simulation》2024年第4期575-589,共15页建筑模拟(英文)
基 金:This work is supported by the National Key Research and Development Program(No.2018YFC0705305);the Fundamental Research Funds for the Central University of Donghua University(No.2232017A-09).
摘 要:The acceleration of industrialization worsening indoor environments of industrial buildings has drawn more attention in recent years.Natural ventilation can improve indoor air quality(IAQ)and reduce carbon emissions.To evaluate gaseous pollutant levels in industrial buildings for the development of buoyancy-driven natural ventilation,two theoretical models of pollutant flushing(Model I and Model II)are developed based on the existing thermal stratification theory in combination with the mixing characteristics of lower pollutant.The results show that indoor pollutant flushing is mainly dependent on the pollution source intensity and effective ventilation area.The mixing characteristics of lower pollutant has an important effect on pollutant stratification and evolution during ventilation,but it does not change the prediction results at steady state.When the dimensionless pollution source intensity is larger than 1,the pollution source should be cleaned up or other ventilation methods should be used instead to improve IAQ.In addition,the comparisons between Model I and Model II on instantaneous pollutant concentration are significantly influenced by the pollution source intensity,and the actual pollutant concentration is more likely to be between the predicted values of Model I and Model II.To reduce pollutant concentration to a required level,the pollution source intensity should be in a certain range.The theoretical models as well as the necessary conditions for ventilation effectiveness obtained can be used for the ventilation optimization design of industrial buildings.
关 键 词:industrial buildings buoyancy-driven natural ventilation gaseous pollutants evolution model pollution sources
分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49