摘 要:2019年,多参数监护仪被加入《实施强制管理的计量器具目录》,2020年,检定规程JJG 1163—2019《多参数监护仪》正式实施,对多参数监护仪在技术规范方面提出了新的要求。本文将强制检定工作中遇到的实际问题归纳整理,提出了适用于多参数监护仪的检定工作策略,同时对多参数监护仪静态压力示值测量结果进行了不确定度分析,为开展相关检定工作提供操作建议与技术依据。In 2019,multifunction patient monitoring instruments were added to the Catalogue of Compulsory Management Measuring Instruments,and in 2020,the calibration regulation JJG 11632019 Multifunction Patient Monitoring Instruments was officially implemented,which put forward new requirements for multifunction patient monitoring instruments in terms of technical specifications.This article summarizes the practical problems encountered in compulsory verification work,proposes verification strategies applicable to multifunction patient monitoring instruments,and analyzes the uncertainty of the measurement results of static pressure indications for multifunction patient monitoring instruments,providing operational suggestions and technical basis for carrying out relevant verificationwork.