检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨杉 喻希 罗朝旭 张晓彤 YANG Shan;YU Xi;LUO Zhaoxu;ZHANG Xiaotong(College of Electrical and Information Engineering,Hunan University of Technology,Zhuzhou 412007,China;State Key Laboratory of Electrical Insulation and Power Equipment,Xi’an Jiaotong University,Xi’an 710049,China)
机构地区:[1]湖南工业大学电气与信息工程学院,湖南株洲412007 [2]西安交通大学电力设备电气绝缘国家重点实验室,陕西西安710049
出 处:《电力系统保护与控制》2024年第10期44-53,共10页Power System Protection and Control
基 金:国家自然科学基金项目资助(52207205);湖南省教育厅科学研究项目资助(22C0308)。
摘 要:为了满足配电网不对称短路计算的通用性要求,针对换流器型分布式电源(inverter based distributed generation,IBDG)不对称短路特征的多样性,研究含IBDG配电网的不对称短路电流计算方法。该方法从通用计算模型出发,根据IBDG不对称短路的正负序电流控制原理及在不同控制目标下的短路电流输出特性,结合低电压穿越和限流控制对IBDG输出不对称短路电流的具体要求,建立一种通用的、适用于多种控制目标的IBDG不对称短路正负序等效模型。基于该模型建立含IBDG配电网通用的不对称短路等效电路和计算方程,得到一种适用于多种IBDG控制目标的、配电网任意节点发生任意不对称短路的短路电流通用计算流程。最后,在一个配电网算例中对所提计算方法进行验证,结果表明了所提方法的正确性和有效性。To meet the general requirements for asymmetric short-circuit calculation in distribution networks,a study is conducted on the calculation method with inverter-based distributed generation(IBDG),considering the diverse characteristics of asymmetrical short-circuits caused by IBDG.This method establishes a universal model that is applicable to the equivalent of IBDG asymmetric short-circuit positive and negative sequences with various control objectives.The establishment of this model is based on the principle of positive and negative sequence current control with IBDG asymmetric short-circuit and the short-circuit current output characteristics with different control objectives,as well as the specific requirements of low voltage ride-through and current limiting control for IBDG output asymmetric short-circuit current.Based on this model,a universal asymmetric short-circuit equivalent circuit and calculation equation are established,and a general calculation process for short-circuit current occurring at any node of the distribution network with any asymmetric short-circuit for multiple IBDG control objectives is obtained.Finally,the proposed method is verified in a distribution network example,and the results show that the proposed method is correct and effective.This work is supported by the National Natural Science Foundation of China(No.52207205).
关 键 词:配电网 不对称短路电流计算 换流器型分布式电源 控制原理 通用计算
分 类 号:TM713[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.191.89.16