检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘朋 LIU Peng(United Electrical Intelligent(Shanghai)Testing Technology Co.,Ltd.,Shanghai 201306,China)
机构地区:[1]联电智检(上海)检测技术有限公司,上海201306
出 处:《自动化应用》2024年第9期193-196,共4页Automation Application
摘 要:主要讨论国家电网公司对电力用户申请用电提出的电能质量要求,针对大容量冲击负荷造成并网点电能质量问题的解决方案,以低压电器大电流短路实验室特殊用电需求为案例进行讨论。研究探讨了多种大容量冲击负荷电能质量的解决方案,以为相关工程技术人员提供一定参考。This paper mainly discusses the power quality requirements proposed by State Grid Corporation of China for power users to apply for electricity,and proposes solutions to the power quality problems caused by high-capacity surge loads at grid connection points,takes the special electricity demand of low-voltage electrical equipment high current short circuit laboratory as a case study for discussion.The study explored various solutions for the quality of high-capacity impact load electricity,providing some reference for relevant engineering and technical personnel.
关 键 词:大容量冲击负荷 电能质量 电压波动 动态无功补偿装置 治理方案
分 类 号:TM714[电气工程—电力系统及自动化]