检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张郁文 刘丙才[1] 王红军[1] 田爱玲[1] 任柯鑫 王凯[1] ZHANG Yu-wen;LIU Bing-cai;WANG Hong-jun;TIAN Ai-ling;REN Ke-xin;WANG Kai(Shaanxi Province Key Laboratory of Thin Films Technology and Optical Test,Xi’an Technological University,Xi’an 710021,China)
机构地区:[1]西安工业大学陕西省薄膜技术与光学检测重点实验室,陕西西安710021
出 处:《中国光学(中英文)》2024年第3期640-647,共8页Chinese Optics
基 金:国家基础科研项目(No.JCKY2020426B009);陕西省科技厅“科学家+工程师”队伍项目(No.2023KXJ-066)。
摘 要:为了对同步相移横向剪切干涉系统中偏振器件的选型、装调以及误差补偿提供可靠的理论依据,本文根据琼斯矩阵原理,构建了系统中1/4波片和偏振片阵列误差对测量结果影响程度的误差模型,对四分之一波片的相位延迟误差、快轴方位角误差以及偏振片阵列透光轴方位角误差对测量结果的影响进行了定量分析。仿真结果表明:1/4波片的相位延迟误差在±1°以内时,波面测量误差为0.00002λ(PV)和0.000062λ(RMS);1/4波片的调整精度在±2°以内时,波面测量误差为0.0001λ(PV)和0.00006λ(RMS);偏振片阵列方位角误差在±1°以内时,测量误差为0.003λ(PV)和0.001λ(RMS)。根据仿真结果对测量系统中偏振元器件进行选型,同时选择两种不同精度的偏振元器件进行对比实验。实验结果的残差值与仿真结果的残差值的PV以及RMS值偏差均小于λ/20,可以在一定程度上验证模型的有效性。本文提出的数学模型可以为同步相移横向剪切干涉系统中偏振器件的选型提供可靠的理论依据。To provide a reliable theoretical basis for the selection,mounting,and error compensation of the polarization device in the synchronous phase-shift transverse shear interference system,based on the Jones matrix principle,we construct an error model reflecting the degree of influence of the errors of quarter-waveplate and polarizer array on the measurement results in the system.Then,we quantitatively analyze how the measurement results are influenced by the following factors:the phase delay error of quarter-waveplate,fastaxis azimuthal angle error,and transmission-axis azimuthal angle error of the polarizer array.The simulation results show that the wavefront measurement errors are 0.00002λ(PV)and 0.000062λ(RMS)when the phase delay error of the quarter-waveplate is within±1°,0.0001λ(PV)and 0.00006λ(RMS)when the adjustment accuracy of the quarter-waveplate is within±2°,and 0.003λ(PV)and 0.001λ(RMS)when the azimuthal angle error of the polarizer array is within±1°.According to the simulation results,the polarization components in the measurement system were selected.At the same time,two polarization components with different levels of accuracy were chosen for comparison experiments.The experimental results indicate the following conclusions:the deviations of the residual values of the experimental results from the residual values of the simulation results in terms of the PV and the RMS values are less thanλ/20,and the validity of the model can be verified to a certain extent.The mathematical model proposed in this paper can provide a reliable theoretical basis for the selection of polarization devices in synchronous phase-shifted transverse shear interference systems.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.70