检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:庞旭 PANG Xu(Zhenjiang Construction Engineering Quality Inspection Centre Limited,Zhenjiang Jiangsu 212004,China)
机构地区:[1]镇江市建设工程质量检测中心有限公司,江苏镇江212004
出 处:《工程质量》2024年第S01期135-137,144,共4页Construction Quality
摘 要:为了研究新风热回收机组的节能效果,本课题以镇江地区某住宅楼为例,通过现场实测和理论计算的方法开展相关研究,研究表明新风热回收机组在冬夏两季节能效果明显,全年节约电量达到777.42kWh。论文的研究对于本地区新风系统节能技术的设计应用具有一定的参考意义。In order to study the energy-saving effect of the heat recovery fresh air unit,this study took a residential building in Zhenjiang as an example,and carried out relevant research through field measurement and theoretical calculation,the results show that the energy saving effect of the fresh air heat recovery unit is obvious in winter and summer,and the annual energy saving reaches 777.42kWh.The research in this paper has certain reference significance for the design and application of energy-saving technology of fresh air system in this area.
分 类 号:TU834.35[建筑科学—供热、供燃气、通风及空调工程]