Sensitive measurement of silver ions in environmental water samples integrating magnetic ion-imprinted solid phase extraction and carbon dot fluorescent sensor  被引量:1

在线阅读下载全文

作  者:Shuangying Li Qingxiang Zhou Zhi Li Menghua Liu Yanhui Li 

机构地区:[1]State Key Laboratory of Heavy Oil Processing,College of Chemical Engineering and Environment,China University of Petroleum-Beijing,Beijing 102249,China

出  处:《Chinese Chemical Letters》2024年第5期272-276,共5页中国化学快报(英文版)

基  金:supported by the National Natural Science Foundation of China(No.21976211).

摘  要:Increasing use of silver in various fields has caused Ag^(+)pollution in water environment,taking great threats to people’s health.As a consequence,establishing rapid and reliable methods for sensitive determination of Ag^(+)is of great significance.Fluorescent(FL)sensors based on carbon dots(CDs),an excellent carbonaceous nanomaterial with strong and stable fluorescence,have absorbed extensive attentions in analysis of pollutants due to its advantages of carbon sources being readily available,low cost,easy operation and fast response.Moreover,ion-imprinting is a better way to increase the selectivity of the proposed method.Present work described an effective method for the sensitive measurement of silver ion in water samples in combination with magnetic ion-imprinted solid phase extraction and CDs based fluorescent sensor,which took full advantages of easy separation and high enrichment of magnetic solid phase extraction,high selectivity of ion-imprinting technology,and sensitivity and rapid response of fluorescent sensor from CDs.Sulfur-doped CDs derived from dithizone and magnetic ion-imprinted nanomaterial were prepared,and characterized with Fourier transform infrared spectroscopy and transmission electron microscope,etc.Magnetic Ag^(+)imprinted nanomaterial based solid phase extraction was employed for separating and enriching Ag^(+)from water samples.The significant parameters were optimized in detail.Under the optimal conditions,the proposed method provided good linearity in the range of 0.01-0.4μmol/L and low detection limit of 3 nmol/L.The reliability of the proposed method was validated with real water samples,and the results demonstrated that the proposed method was simple,robust,selective and sensitive detection tool for Ag^(+)in real water samples.

关 键 词:Carbon dots Ag^(+) Magnetic ion-imprinting Magnetic solid phase extraction Fluorescent sensor 

分 类 号:O657.3[理学—分析化学] X832[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象