摘  要:辐射型反射隔热涂料在夏热冬冷地区居住建筑中的应用案例越来越多,其节能设计方法备受关注。等效热阻法是目前反射隔热涂料热工设计的标准方法,但相关文献研究指出,涂覆于非透明材料上的隔热涂料应采用太阳光直接反射比作为隔热评价指标,不宜用等效热阻来评价。通过上海某6层住宅建筑探讨了夏热冬冷地区居住建筑外墙采用辐射型反射隔热涂料的节能效果及其传热系数、太阳辐射吸收系数和表面发射率之间的关系,对比分析了采用参数直接计算与等效热阻法计算能耗结果,结果表明:1)辐射型反射隔热涂料隔热机理与反射隔热涂料差异明显;2)辐射型反射隔热涂料节能效果不适宜采用等效热阻法进行节能效果评价;3)辐射型反射隔热涂料墙体冬季保温热阻设计应充分考虑其对墙体温度的负面影响。More and more radiation-type thermal insulation coatings are used on the residential buildings in the hot summer and cold winter zone and the thermal performance design methods are also receiving more attentions.The equivalent thermal resistance method is specified by the standard JGJ/T359 for considering the effect of the thermal reflective insulation coatings.However,some literature researches indicates that the energy efficiency used the thermal reflective insulation coatings on the non-transparent fagades should be evaluated by the solar reflective as the insulation evaluation index rather than the equivalent thermal resistance.This paper is to discuss the energy efficiency of using radiation-type thermal insulation coatings on the outside of the exterior walls of residential buildings in hot summer and cold winter areas in Shanghai,and the relationship between the energy consumption of the air conditioner,heat transfer coeficient,solar radiation absorption coefficient,and surface emissivity of the wall is studied.The energy consumption results are calculated using the thermal parameters directly and that of using the equivalent thermal resistance method are also carried out.The results shown that:1)The insulation mechanism of the radiation-type thermal insulation coatings is significantly different from that of the reflective insulation coatings;2)The energy-saving effect of the radiation-type thermal insulation coatings is not suitable evaluated by using the equivalent thermal resistance method;3)The design of the winter insulation thermal resistance of the wall using the radiation-type thermal insulation coatings should fully consider its negative impact on wall's temperature in the winter nightime.

关 键 词:辐射型反射隔热涂料 夏热冬冷地区 居住建筑 节能评价方法 

分 类 号:TU111[建筑科学—建筑理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象