作 者:章双双 ZHANG Shuangshuang(Equipment Department,Gaoyou People's Hospital,Gaoyou,Jiangsu 225600,China)
出 处:《中国医学工程》2024年第6期37-41,共5页China Medical Engineering
摘 要:目的减少设备故障的发生,提高临床科室对输注泵的利用率,在设备精准度不足方面进行PDCA循环方法,进一步提高设备质量管理水平。方法以高邮市人民医院输注泵为基数,对临床科室定期巡查,查找出人、机、料、环等方面的问题,利用鱼骨图分析原因,输液设备分析仪IDA-1S进行质控检测,不断加强人员培训进行改进并巩固相关措施。结果通过PDCA有效改善了输注泵存在的问题,故障率明显下降,并进行质控测试,有效保证了设备使用的精准度和稳定性。结论PDCA是一种有效的分析方法,将其与设备质控检测相结合,强化职能科室对医疗设备的综合性管理。【Objective】To reduce the occurrence of equipment failure,improve the utilization rate of infusion pump in clinical departments,and carry out PDCA cycle method in the aspect of equipment accuracy deficiency,so as to further improve the quality management level of equipment.【Methods】Based on the infusion pump of Gaoyou People's Hospital,regular inspection of clinical departments was conducted to find out the problems in human,machine,material and environment and the causes were analyzed using fishbone diagram.Transfusion equipment analyzer IDA-1S was used for quality control testing,and personnel training was constantly strengthened to improve and consolidate relevant measures.【Results】PDCA effectively improved the problems existing in the infusion pump,the failure rate was significantly reduced,and the quality control test was carried out to effectively ensure the accuracy and stability of the equipment.【Conclusion】PDCA is an effective analysis method,which can be combined with equipment quality control and testing to strengthen the comprehensive management of medical equipment in functional departments.
分 类 号:R197.39[医药卫生—卫生事业管理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.12.164.78