基于热集成的轻烃回收装置气体分馏系统用能优化  

Energy-use optimization of gas fractionation system inlight ends recovery unit based on heat integration

在线阅读下载全文

作  者:李兴涛 韩莎莎 何畅 张冰剑 陈清林 Li Xingtao;Han Shasha;He Chang;Zhang Bingjian;Chen Qinglin(School of Materials Science and Engineering,Sun Yat-sen University,Guangzhou,Guangdong 510006;School of Chemical Engineering and Technology,Sun Yat-sen University,Zhuhai Guangdong 528478;Guangdong Engineering Center for Petrochemical Energy Conservation,Guangzhou,Guangdong 510275)

机构地区:[1]中山大学材料科学与工程学院,广东省广州市510006 [2]中山大学化学工程与技术学院,广东省珠海市528478 [3]广东省石化过程节能工程技术研究中心,广东省广州市510275

出  处:《炼油技术与工程》2024年第5期5-11,共7页Petroleum Refinery Engineering

基  金:国家自然科学基金(Nos.22078373)。

摘  要:针对轻烃回收装置气体分馏系统进行模拟分析与用能优化,并基于Aspen Plus流程模拟,探讨了进料温度、回流比对系统能耗的影响。考虑到炼化低温余热相对富余,结合工艺分析和精馏序列优化,并改善热源、热阱的不匹配性,降低脱乙烷塔和脱丁烷塔塔底温度,提出了集成热媒水系统、热泵系统的气体分馏改进工艺以降低装置能耗,并对改进前后的能效和经济性进行了对比分析。结果表明:4种改进方案均可降低气体分馏系统能耗15.61%以上,年净效益151.80万元以上。集成热媒水系统的改进工艺㶲耗量降低0.52 MW,降幅达40.95%,年净效益400.57万元,投资回收期为0.42 a。集成直接式热泵系统的改进工艺方案改进效果最佳,过程㶲耗量降低0.67 MW,降幅达53.04%,年净效益498.18万元,投资回收期为1.41 a。Based on rigorous process simulation in Aspen Plus,energy optimization is conducted on the gas fractionation system in a light ends recovery unit,with a focus on exploring the effects of feed temperature and reflux ratio on system energy consumption.Considering the relative surplus of low temperature heat in refineries,the bottom temperature of deethanizer and debutanizer towers are reduced based on process analysis and distillation sequence optimization to improve the mismatch between heat sources and heat sinks.The improved gas fractionation processes integrating with hot medium water system and heat pump system are proposed to reduce device energy consumption of the unit,and a comparative analysis is conducted on the energy efficiency and economy before and after the improvement.The results obtained show that all four improved schemes could reduce the energy consumption of the unit by more than 15.61%and achieve an annual income of over 1.518 million yuan.The improved scheme integrating with hot medium water system reduces exergy consumption by 0.52 MW and 40.95%,with an annual income of 4.0057 million yuan and a payback period of 0.42 years.The improved scheme integrating with direct heat pump system has the best effect,with a reduction of 0.67 MW and 53.04%in the usage of exergy and an annual income of 4.9818 million yuan,with a payback period of 1.41 years.

关 键 词:热集成 轻烃回收装置 气体分馏系统 用能优化 能效分析模型 经济分析模型 直接式热泵 间接式热泵 

分 类 号:TE96[石油与天然气工程—石油机械设备]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象