两级AO-臭氧催化氧化-后置反硝化-BAF工艺处理焦化废水工程实例  被引量:3

A project example of treatment of coking wastewater by two stage AO-catalytic ozonation-post denitrification-BAF process

在线阅读下载全文

作  者:徐娟娟 熊耀 王立媛 韦凤密 XU Juanjuan;XIONG Yao;WANG Liyuan;WEI Fengmi(Beijing Zhongke Kanglun Energy Technology Co.,Ltd.,Beijing 102627,China;Beijing Cycle Columbus Environmental Science and Technology Co.,Ltd.,Beijing 100088,China)

机构地区:[1]北京中科康仑能源科技有限公司,北京102627 [2]北京赛科康仑环保科技有限公司,北京100088

出  处:《工业用水与废水》2024年第3期96-100,共5页Industrial Water & Wastewater

摘  要:焦化废水污染物成分复杂,难生物降解污染物占比大,某工程项目设计采用两级AO-臭氧催化氧化-后置反硝化-BAF工艺处理焦化废水,介绍了该工程的工艺流程及特点、设计参数和运行效果。运行结果表明,在系统来水COD质量浓度为5746~7283 mg/L,氨氮质量浓度为91.4~130.1 mg/L时,处理出水COD质量浓度为40~55 mg/L,氨氮质量浓度小于2 mg/L,出水稳定达到设计目标,有利于后续膜回用系统的正常运行。Coking wastewater has complex pollutants composition,which contains a large proportion of difficult biodegradable pollutants.Two stage AO-catalytic ozonation-post denitrification-BAF process was adopted in the design of a project treating coking wastewater,the process flow,characteristics,design parameters and operation effect of the said project were introduced.The operation results showed that,when the mass concentrations of COD and ammonia nitrogen in the influent water of the system were 5746-7283 and 91.4-130.1 mg/L respectively,after the treatment,the mass concentrations of COD and ammonia nitrogen were 40-55 and lower than 2 mg/L respectively.The effluent water quality was stable and reached the design goal,which was conducive the the normal operation of the subsequent membrane reuse system.

关 键 词:焦化废水 两级AO 臭氧催化氧化 后置反硝化 BAF 废水处理 

分 类 号:X703.1[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象