检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:魏娟[1] 张雪晶 陈廷敏 刘永 王新岭 WEI Juan;ZHANG Xuejing;CHEN Tingmin;LIU Yong;WANG Xinling(School of Mechanical Engineering,Xi'an University of Science and Technology,Xi'an 710054,China;Ningxia Zhonghao Yinchen energy Technology Service Co.Ltd.,Shizuishan 753400,Ningxia,China)
机构地区:[1]西安科技大学机械工程学院,西安710054 [2]宁夏中昊银晨能源技术服务有限公司,宁夏石嘴山753400
出 处:《新能源进展》2024年第3期343-352,共10页Advances in New and Renewable Energy
摘 要:为降低西北地区居民使用太阳能复合供暖系统的经济成本和碳排放量,并提高太阳能利用率,设计一种太阳能-热泵双水箱复合供暖系统,并优化其重要参数。利用Dymola平台,搭建太阳能-热泵双水箱复合供暖系统模型,目标函数是系统全生命周期成本,选取太阳能集热器面积、集热器安装倾角、水箱容量和热泵功率作为优化变量,采用遗传算法同步优化系统所选变量,并对系统的环保性进行分析。以宁夏地区为案例进行优化计算,结果表明,所创建的数学模型准确性较好,比较模拟数据与实验数据,二者平均误差均在±8%以内。在系统15年寿命周期内,优化后系统性能系数提高10.3%,水箱平均温度提高至54.71℃,系统生命周期成本减少5.3%,节能率为24.4%,节能效果显著。系统的SO_(2)、CO_(2)、NOx及烟尘的减排量分别为0.82、26.6、0.41、7.48t,该系统可以显著降低环境影响,与传统燃煤锅炉相比减排效果显著。In order to reduce the economic cost and carbon emissions of the solar composite heating system for residents in northwest China,and improve the utilization rate of solar energy,a composite heating system of double tanks solar-energy heat pump was designed and its important parameters were optimized.Based on the Dymola platform,a complete dual tanks solar-energy heat pump composite heating system model was established.The objective function was the entire life cycle of the system,and the solar collector area,collector installation angle,water tank capacity and heat pump power were selected as the optimization variables,and the genetic algorithm was used to synchronously optimize the selected variables of the system.Besides,the environmental friendliness of the system was analyzed.In this paper,the optimization calculation was carried out in the Ningxia region.The research results indicated that the mathematical model created was highly accurate,and the average error between the two was about±8%compared to simulation data and experimental data.During the 15-year life cycle of the system,the life cycle cost of the system decreased by 5.3%,the coefficient of performance of the optimized system increased by 10.3%,the average temperature of the water tank raised to 54.71 oC,the energy saving rate was 24.4%,which was significant.The emission reduction of SO_(2),CO_(2),NOx,and soot of the system were 0.82,26.6,0.41 and 7.48 t respectively,with significant emission reduction effect compared with the traditional coal-fired boiler.
分 类 号:TK519[动力工程及工程热物理—热能工程] TU832[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.133.149.244