摘  要:针对目前国产电动海水提升泵电机绝缘失效率高、质量不够稳定的问题,结合实际案例,通过温度场仿真分析等方法,得出潜海水电机绝缘失效的主要原因包括绕组线选型缺陷、内部散热不足、密封性能差和缺少温度监控。针对上诉原因,逐条提出可行的改进方法,提高电动潜海水泵的产品质量。Aiming at the problems of high insulation failure rate and unstable quality of domestic electric seawater lifting pump motor.By combining the actual cases and the simulation analysis of temperature field,it is concluded that the main reasons for the insulation failure of submerged water motor include the defect of winding wire selection,insufficient internal heat dissipation,poor sealing performance and lack of temperature monitoring.At the same time,according to the reason of appeal,the feasible improvement method is put forward in order to improve the product quality of electric submersible water pump.