丙烯制冷压缩机一段吸入罐液位高的原因分析及对策  

CAUSE ANALYSIS AND COUNTERMEASURES FOR HIGH LIQUID LEVEL IN FIRST STAGE SUCTION TANK OF PROPYLENE REFRIGERATION COMPRESSOR

在线阅读下载全文

作  者:杨盼 龙先煌 梁多 白仲辉 杨志楠 Yang Pan;Long Xianhuang;Liang Duo;Bai Zhonghui;Yang Zhinan(PetroChina Tarim Petrochemical Company,Kolar,Xinjiang,P.C.841000)

机构地区:[1]中国石油天然气股份有限公司塔里木石化分公司,新疆库尔勒841000

出  处:《乙烯工业》2024年第2期57-59,I0002,共4页Ethylene Industry

摘  要:以某乙烯装置丙烯制冷压缩机系统为例,从实际开工运行后出现一段吸入罐液位持续高的问题入手,通过现场实际查找以及探讨论证后,分析得出设计与实际运行存在差异的根本原因是一段吸入罐顶的温控阀内漏。在装置运行期间采取工艺调整、新增热线等措施切实有效地解决了问题,从而保证了丙烯制冷压缩机安全平稳长周期运行。This paper takes the propylene refrigeration compressor system of an ethylene plant as an example,and analyzes the problem that the liquid level in the first stage suction tank continues to be high during actual operation.After field investigation and discussion,it is concluded that the root cause of the difference between design and actual operation is the internal leakage of the temperature control valve on top of the first stage suction tank.During the operation of the ethylene plant,such measures as making process adjustment and installing a new pipeline for transporting hot propylene gas were taken to effectively solve this problem,thus ensuring the safe,stable and long-term operation of the propylene refrigeration compressor.

关 键 词:丙烯制冷 一段吸入罐 液位高 

分 类 号:TQ051.21[化学工程] TQ221.211

 