检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李振东 陈丹 杨光 LI Zhendong;CHEN Dan;YANG Guang(Department of Cardiac Surgery,Wuxi Mingci Cardiovascular Hospital,Wuxi 214024,China)
机构地区:[1]无锡明慈心血管病医院心脏外科,江苏无锡214024
出 处:《河南医学研究》2024年第12期2141-2144,共4页Henan Medical Research
摘 要:目的 研究累及左锁骨下动脉(LSA)的Standford B型主动脉夹层(TBAD)中castor分支型覆膜支架(简称castor支架)的应用效果及对主动脉重塑的影响。方法 纳入无锡明慈心血管病医院收治的58例TBAD患者,根据治疗方法分为castor组(31例)和对照组(27例)。对照组接受烟囱技术,castor组接受castor支架进行治疗。比较两组的手术相关指标、围手术期并发症。对两组进行随访,比较随访期间上肢缺血、脑梗死、内漏、LSA窃血、夹层逆撕等晚期并发症的发生率。比较两组术后2周和术后6个月时的主动脉重塑指标。结果 castor组透视时间、手术时间均长于对照组(P<0.05)。castor组围手术期并发症发生率低于对照组(P<0.05)。castor组随访期间晚期并发症发生率低于对照组(P<0.05)。术后6个月,castor组假腔完全血栓化比率高于对照组(P<0.05)。结论 虽然与烟囱技术相比,castor支架治疗累及LSA的TBAD透视时间和手术时间延长,但是围手术期并发症和晚期并发症发生率较低,且有助于患者的假腔血栓化。Objective To study the effect of castor branch covered stent(castor stent)in Standford type B aortic dissection(TBAD)involving the left subclavian artery(LSA)and its influence on aortic remodeling.Methods A total of 58 TBAD patients admitted to Wuxi Mingci Cardiovascular Hospital were divided into castor group(31 cases)and control group(27 cases)based on treatment methods.The control group received chimney technology,while the castor group received castor stents for treatment.The surgical related indicators and perioperative complications between the two groups were compared.The incidence of late complications such as upper limb ischemia,cerebral infarction,internal leakage,LSA steal,and dissection reverse tearing during the follow-up period between the two groups were compared.The aortic remodeling indicators between the two groups at 2 weeks and 6 months after surgery were compared.Results The fluoroscopy time and surgical time in the castor group were longer than those in the control group(P<0.05).The incidence of perioperative complications in the castor group was lower than that in the control group(P<0.05).The incidence of late complications during follow-up in the castor group was lower than that in the control group(P<0.05).At 6 months after surgery,the false lumen complete thrombosis rate in the castor group was higher than that in the control group(P<0.05).Conclusion Although castor stent treatment involves longer TBAD fluoroscopy time and surgical time for LSA compared to chimney technology,the incidence of perioperative and late complications are lower,and it helps patients with false lumen thrombosis.
关 键 词:左锁骨下动脉 Standford B型主动脉夹层 castor分支型覆膜支架 主动脉重塑
分 类 号:R543.1[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.85.3