Accuracy and precision of dried urine spot method for the detection of Schistosoma mansoni circulating cathodic antigens in resource-limited settings  

在线阅读下载全文

作  者:Abdallah Zacharia Clemence Kinabo Twilumba Makene Huda Omary George Ogweno Faraja Lyamuya Billy Ngasala 

机构地区:[1]不详

出  处:《Infectious Diseases of Poverty》2024年第1期103-104,共2页贫困所致传染病(英文)

摘  要:Background The World Health Organization recommends the use of Schisto point-of-care circulating cathodic anti-gens(Schisto POC-CCA)for screening of Schistosoma mansoni as it offers better sensitivity than microscopy.However,there are limitation facing the use of this method including timely availability of the test cassettes.The aim of this study was to determine the reliability of dried urine spot(DUS)method for collection of urine and detection of S.mansoni using Schisto POC-CCA cassettes in a resource-limited settings.Methods A cross-sectional study was conducted between October and November 2022 among 250 primary school children in Sengerema District,northwestern Tanzania.S.mansoni CCA was detected in filter paper-based DUSs,liquid urine using DUS Schisto POC-CCA(index),and direct urine Schisto POC-CCA(comparator)methods respectively.S.mansoni eggs in stool were detected using duplicate Kato-Katz(KK)method.The measures of accuracy were com-puted and compared between the index and comparator methods.The strength of agreement between inter-raters precisions was tested using Cohen's kappa(k).Results This study revealed S.mansoni prevalence rates of 28.8%,54.0%and 50.8%by duplicate KK,direct urine Schisto POC-CCA and DUS Schisto POC-CCA methods respectively.The mean intensity of infection among infected participants Was 86.3 eggs per gram of stool(EPG)ranging from 12.0 EPG to 824.0 EPG.The sensitivity of DUS Schisto POC-CCA and direct urine Schisto POC-CCA Was 94.44%(95%CI:89.15-99.74%)and 97.22%(95%CI:93.43-100.00%)respectively.The DUS Schisto POC-CCA method had slightly higher specificity(66.85%)than direct urine Schisto POC-CCA method(63.48%).The accuracy of the DUS Schisto POC-CCA Was found to be slightly high(74.80%,95%CI:68.94-79.06%)compared to that of direct urine Schisto POC-CCA(73.20%,95%CI:67.25-78.59%).There was good agreement between two laboratory technologists who performed the DUS Schisto POC-CCA method on similar samples(k=0.80,95%CI:0.59-0.95).Conclusions The DUS Schisto POC-CCA method had comp

关 键 词:ACCURACY Point-of-care circulating cathodic antigen Dried urine spot Schistosoma mansoni Sensiti Specificity 

分 类 号:R532.21[医药卫生—内科学] R446.5[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象