一起电缆中间头故障的分析及解决方案  被引量:1

Analysis and Solution of a Case of F aults on Intermediate Joints of Cable

在线阅读下载全文

作  者:叶念 YE Nian

机构地区:[1]中铁武汉电气化局集团有限公司

出  处:《电气化铁道》2024年第3期86-89,共4页Electric Railway

摘  要:针对某地铁工程高架区间环网电缆中间头部位发生的绝缘击穿事件,详细分析故障原因,结合电缆外护套材料原理,探讨电缆外护套收缩的原因,并从电缆制造、招标、设计施工及运营维护等环节给出相应的解决方案。With regard to an incident of insulation breakdown that occurred at an intermediate joint of a ring network cable in an elevated section of a subway project,a detailed analysis of causes of the fault is made.Combining with the principle of cable outer sheath material,the reasons for shrinkage of cable outer sheath are discussed,and corresponding solutions are provided from aspects of cable manufacturing,bidding,design and construction as well as aspects of operation and maintenance.

关 键 词:电缆护套 收缩 绝缘击穿 电缆中间头 

分 类 号:U231.8[交通运输工程—道路与铁道工程]

 