某超临界锅炉过热器T91管爆管原因分析  

Cause Analysis of T91 Tube Burst in a Supercritical Boiler Superheater

在线阅读下载全文

作  者:原永亮 YUAN Yongliang(Datang Northeast Electric Power Test&Research Institute,Changchun 130051,China)

机构地区:[1]大唐东北电力试验研究院有限公司,长春130051

出  处:《吉林电力》2024年第3期5-7,共3页Jilin Electric Power

摘  要:针对某超临界锅炉发生的高温过热器爆管事件,首先,通过宏观检验、显微组织分析、力学性能试验等方面对现场进行分析,研究发现高温过热器达到了氧化皮脱落的高峰期,氧化皮堵塞斜U型弯管,造成管壁超温,最终在T91材质位置过热爆管。最后,提出氧化皮防治措施。In response to the high-temperature superheater tube explosion incident that occurred on a certain supercritical boiler,this article analyzed macroscopic inspection,microstructure analysis,mechanical performance tests,and other aspects.It was found that the high-temperature superheater reached the peak period of oxide skin peeling,blocked the inclined U-shaped bend,caused the tube wall to overheat,and ultimately overheated and burst at the T91 material position.Finally,propose measures to prevent oxidation skin.

关 键 词:过热器 氧化物堵塞 爆管 

分 类 号:TK223.3[动力工程及工程热物理—动力机械及工程]

 