检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:鲁力铭 LU Liming(School of Electrical Engineering,Xi′an Jiaotong University,Xi′an 710049,Shaanxi,China)
机构地区:[1]西安交通大学电气工程学院,陕西西安710049
出 处:《四川电力技术》2024年第3期101-105,共5页Sichuan Electric Power Technology
摘 要:高压电抗器因密封不良从外部进水或其内部固体绝缘材料严重老化生成水,均会导致绝缘油中水分增加并表现出受潮缺陷。针对某500 kV高压电抗器绝缘油受潮缺陷,基于油质、油中溶解气体含量、油中水分等绝缘油理化指标对其受潮原因进行分析,判断出该受潮缺陷不是外部进水而是内部固体绝缘材料老化引起的;通过现场真空密封试验,未发现外界水分进入电抗器的通道,进一步验证了所用方法分析判断受潮原因的正确性。Poor sealing of high-voltage reactors can cause an increase in moisture content in insulation oil and the appearance of moisture defects due to external water ingress or severe aging of internal solid insulation materials.There are no relevant literature reports on how to determine whether the moisture defects in high-voltage reactors are caused by external water ingress or internal aging of insulation paper based on the physicochemical indicators of insulation oil.Based on physical and chemical indicators such as oil quality,dissolved gas content in oil and water content in oil,the reasons for insulation oil to become damping in a 500 kV high-voltage reactor are analyzed,which concludes that it is not caused by external water ingress but internal solid insulation material aging.Through vacuum sealing tests on site,no channel for external water to enter the reactor is found,which further verifies that the insulation oil of that high-voltage reactor to become damping is caused by internal solid insulation material aging.
分 类 号:TM855[电气工程—高电压与绝缘技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7