某超高层建筑空调冷凝水回收系统设计  

Design of Condensate Water Recovery System for Air Conditioning in a Super High-rise Building

在线阅读下载全文

作  者:周庆申 ZHOU Qingshen(Guangdong Beilin Architectural Design Co.,Ltd.,Guangzhou 511400)

机构地区:[1]广东贝林建筑设计有限公司,广州511400

出  处:《制冷》2024年第2期35-38,共4页Refrigeration

摘  要:本文浅述空调冷凝水回收用于冷却水系统补水相关技术,并总结冷凝水开式回收和闭式回收的差异。介绍了空调冷凝水产水量、冷却塔补水量冷却塔补水水箱容量的计算方法,并以此为基础,结合广州某超高层建筑,对其空调冷凝水回收系统进行设计应用,为今后空调冷凝水回收系统设计提供参考。This article introduces the technologies related to the use of air conditioning condensate recovery for cooling water system replenishment,and summarizes the differences between open and closed condensate recovery.This article elaborates on the calculation method for the water volume of air conditioning condensate and the capacity of the cooling tower makeup water tank.Based on this,taking the air conditioning system of a super high-rise building in Guangzhou as an example,the design of the air conditioning condensate recovery system is carried out,providing reference for the future design of the air conditioning condensate recovery system.

关 键 词:超高层建筑 空调冷凝水 回收利用 

分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]

 