利用ICP光谱仪测定硅基材料中镁含量的方法  

Methods for Determining Magnesium Content in Silica-based Materials with ICP(Inductively Coupled Plasma)Spectrometer

在线阅读下载全文

作  者:程娟 刘敏静 耿艳辉 谷强 屈春花 Cheng Juan;Liu Min-jing;Geng Yan-hui;Gu Qiang;Qu Chun-hua(Inner Mongolia Shanshan Science and Technology Co.,Ltd.,Baotou 014010,Inner Mongolia Autonomous Region,China)

机构地区:[1]内蒙古杉杉科技有限公司,内蒙古包头014010

出  处:《包钢科技》2024年第2期89-91,共3页Science & Technology of Baotou Steel

摘  要:文章主要对硅基复合材料中镁含量的检测方法进行了研究,其检测目的是准确地检测出在制备硅基复合材料过程中镁的含量,从而对最终产物中的硅酸镁含量进行控制。在实验过程中建立了用电感耦合等离子体发射光谱法(ICP-AES)测定硅酸镁-碳包覆氧化亚硅复合材料中镁含量的方法,最终验证其检出限为0.004 mg/L,检测结果的相对标准偏差均小于5%,线性相关系数达到0.999以上,该方法满足镁含量的测定。In the paper,the detection method of magnesium content in silica-based composite material is studied and its purpose is to accurately detect magnesium content in the process of preparing silica-based composite materials so as to control the content of magnesium silicate in final product.During the experiment,the method for determining magnesium content in magnesium silicate-carbon-encapsulated silicon oxide composite material with the inductively coupled plasma atomic emission spectrometry(ICP-AES)is established.Finally,it is verified that the detection limit is 0.004 mg/L,relative standard deviation of detection results is less than 5%and linearly dependent coefficient is above 0.999 so that this method is satisfied with the test of magnesium content.

关 键 词:硅基复合材料 镁含量 消解 ICP测试 

分 类 号:TQ132.2[化学工程—无机化工]

 