检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张瑞卿 ZHANG Ruiqing(Ningjin Ecological Environment Monitoring Center of Xingtai City,Xingtai 055550,China)
机构地区:[1]邢台市宁晋生态环境监控中心,河北邢台055550
出 处:《中国资源综合利用》2024年第6期49-51,共3页China Resources Comprehensive Utilization
摘 要:总氮是水质监测的重要指标,多项环境标准均对总氮限值有要求。碱性过硫酸钾分光光度法为测定总氮的常用方法,控制总氮测定过程中空白值对提高水质总氮监测数据的准确性具有重要意义。主要研究4种过硫酸钾试剂对总氮空白值的影响,不同厂家过硫酸钾试剂空白值差异显著。使用重结晶过硫酸钾能显著降低过硫酸钾空白值,同时控制试验条件,能够有效提高总氮测定准确度。Total nitrogen is a crucial indicator in water quality monitoring,with multiple environmental standards setting total nitrogen limits.Alkaline potassium persulfate spectrophotometry is a common method for total nitrogen determination.Controlling the blank value during total nitrogen measurement is vital for data accuracy.This study examines the impact of four potassium persulfate reagents on total nitrogen blank values,revealing significant differences between manufacturers.Recrystallized potassium persulfate significantly reduces blank values,and controlling experimental conditions effectively enhances total nitrogen measurement accuracy.
分 类 号:X832[环境科学与工程—环境工程]