固体氧化物电解池平行流道流动不均匀性优化模拟  

Simulations on Flow Non-uniformity in Parallel Channel of Solid Oxide Electrolysis Cells

在线阅读下载全文

作  者:章大海[1] 史晓锋 侯啸海 罗云[1] 蒋文春[1] ZHANG Dahai;SHI Xiaofeng;HOU Xiaohai;LUO Yun;JIANG Wenchun(College of New Energy,China University of Petroleum(East China),Qingdao 266580,Shandong,China)

机构地区:[1]中国石油大学(华东)新能源学院,山东青岛266580

出  处:《硅酸盐学报》2024年第5期1687-1697,共11页Journal of The Chinese Ceramic Society

基  金:山东省自然科学基金资助(ZR2023ME036)。

摘  要:氢能是一种具有高能量密度、无污染的可再生能源。当前,固体氧化物电解水制氢技术(SOEC)对于流场分布的关注较少,而平行流道的流动不均匀性会显著影响SOEC的反应效率和使用寿命。本研究结合燃料电池中对反应物流动情况的研究建立了电化学场、传热场、流场的多物理场耦合仿真模型研究反应物在电解中的分布情况,按照不同的流道宽度比改变平行流道的流道宽度,设计了一种新型Z型平行流场。结果表明:与传统Z型流场相比,8000 A/m^(2)电流密度下水蒸气摩尔分数不均匀系数由0.1520下降至0.0304,电解质局部电流密度差值由6000 A/m^(2)下降至2000 A/m^(2),温差由105.9 K下降至97.2 K,均匀性有明显的提升。各个电流密度下,在出口处的产氢速率上升7%左右,在相同时间内可以产生更多的氢气,提高了制氢的效率。Introduction The importance of environmental protection leads to the development on new energy hydrogen production technology.High-temperature solid oxide hydrogen production technology is widely investigated because of its non-polluting production process and close to 100%hydrogen production efficiency.However,the solid oxide electrolytic cell(SOEC)cannot be commercialized because of its short effective service life,in which the electrode degradation effect caused by the uneven distribution of reactant water vapor is one of the important reasons for the short life span of the SOEC.The flow inhomogeneity of the conventional parallel flow channel significantly affects the reaction efficiency and service life of solid oxide electrolytic cells,and the flow uniformity is dependent on the geometry of the SOEC flow channel.For the flow characteristics of the conventional Z-type solid oxide electrolytic cell,the molar fraction of water vapor gradually decreases from the two ends to the middle region,which affects the performance of SOEC.To improve the uniformity of water vapor distribution from the structure,a new channel structure was designed to change the width of the channel in accordance with a certain cross-sectional area ratio.The cross-sectional area of the channel from the two ends to the middle could be gradually increased to enhance a supply of water vapor in the middle region,so as to make the overall distribution of water vapor in the SOEC more uniform,eliminate the electrode degradation effect and prolong the service life of the solid oxide electrolytic cell.Methods The total cross-sectional area of the entire flow channel remained unchanged.Based on the characteristic of the water vapor mole fraction of the conventional Z-type flow channel that decreases regularly from the two sides to the middle,a control variable method was adopted according to a certain ratio of the width of the flow channel to calculate the size of the cross-sectional area of each channel.Different water vapor mole fractions of the di

关 键 词:固体氧化物电解池 流道结构优化 流场分布 数值模拟 

分 类 号:TQ116.2[化学工程—无机化工]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象