摘  要:针对室外消防临时高压给水系统的供水方式和要求,叙述了室外消防临时高压给水系统的增压方式。分析室外消防临时高压给水系统车载设施增压方式和固定设施增压方式的特点及实用性,并提出采取车载设施增压方式应具备的条件;在列举若干消防规范中对临时高压给水系统压力的相关要求的基础上,依据消防供水压力的配置要求和作用,提出了高层建筑消防临时高压给水系统的压力配置建议思路和要求。According to the water supply mode and requirement of the temporary high-pressure water supply system for outdoor firefighting,and described the pressurization method of the temporary high-pressure water supply system for outdoor firefighting.Analyzing the characteristics and practicality of the pressurization methods for vehicle-mounted and fixed facilities in the temporary high-pressure water supply system for outdoor firefighting,and proposed the conditions for adopting the vehicle-mounted facility pressurization method.On the basis of listing the relevant requirements for the pressure of temporary high-pressure water supply systems in several fire safety regulations,and based on the configuration requirements and functions of fire water supply pressure,and proposed a suggestion and requirement for the pressure configuration of temporary high-pressure water supply systems in high-rise buildings.