检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:余飞[1] 李剑明[2] 张涵 刘海燕[3] 武萍[3] 何薇 尚华[5] 肖俊杰 贠明凯 李殿富[8] 张晓丽[7] 李思进[3] Yu Fei;Li Jianming;Zhang Han;Liu Haiyan;Wu Ping;He Wei;Shang Hua;Xiao Junjie;Yun Mingkai;Li Dianfu;Zhang Xiaoli;Li Sijin(Institute of Nuclear Medicine,Tongji University,Department of Nuclear Medicine,Tenth People's Hospital of Tongji University,Shanghai 200040,China;Department of Nuclear Medicine,TEDA International Cardiovascular Hospital,Tianjin 300457,China;Department of Nuclear Medicine,the First Hospital of Shanxi Medical University,Taiyuan 030001,China;Department of Nuclear Medicine,Huadong Hospital Affillated to Fudan University,Shanghai 200040,China;Department of Nuclear Medicine,the Second Hospital of Hebei Medical University,Shijiazhuang 050000,China;Institute of Cardiovascular Sciences,Shanghai University,Shanghai Engineering Research Center of Organ Repair,Shanghai 200444,China;Department of Nuclear Medicine,Beijing Anzhen Hospital,Capital Medical University,Beijing 100069,China;Department of Cardiology,the First Affiliated Hospital of Nanjing Medical University,Nanjing 210029,China)
机构地区:[1]同济大学核医学研究所,同济大学附属第十人民医院核医学科,上海200040 [2]泰达国际心血管病医院核医学科,天津300457 [3]山西医科大学第一医院核医学科,太原030001 [4]复旦大学附属华东医院核医学科,上海200040 [5]河北医科大学第二医院核医学科,石家庄050000 [6]上海大学心血管研究所,上海器官修复工程技术研究中心,上海200444 [7]首都医科大学附属北京安贞医院核医学科,北京100069 [8]南京医科大学附属第一医院心血管内科,南京210029
出 处:《国际放射医学核医学杂志》2024年第4期207-214,共8页International Journal of Radiation Medicine and Nuclear Medicine
摘 要:PET/CT心肌血流量(MBF)定量技术被认为是目前无创评估MBF和心肌血流储备(MFR)的“金标准”,但由于受正电子心肌灌注显像药物获取困难等多种因素的限制,该技术在我国临床实践工作中开展的并不理想。采用全新半导体碲锌镉(CZT)探测器的心脏专用SPECT定量技术近些年在国内逐步开展,可实现定量评估MBF和MFR。本专家共识介绍了CZT心脏专用SPECT MBF定量技术的相关药物准备、具体步骤及其在临床应用中所提供的诊断与预后价值,希望有助于进一步规范和推广该技术在国内的应用。PET/CT myocardial blood flow(MBF)quantification technique is currently considered to be the'gold standard'for non-invasive assessment of MBF and myocardial flow reserve(MFR).Nevertheless,due to various limitations such as difficulties in obtaining positron-emitting myocardial perfusion imaging agents,this technique is not well developed in clinical practice in China.The cardiac-dedicated SPECT MBF quantification technique equipped with a new semiconductor cadmium zinc telluride(CZT)detector has been used in clinical practice in China recently,which can provide quantitative assessment of MBF and MFR.This expert consensus introduces the related medication preparation,acquisition protocols,and the diagnostic and prognostic value of CZTdedicated SPECT MBF quantitative technology in clinical applications,which in order to further regulate and promote its application in China.
关 键 词:体层摄影术 发射型计算机 单光子 心肌灌注显像 碲锌镉 心肌血流量 心肌血流储备
分 类 号:R817.4[医药卫生—影像医学与核医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.201.49