基于超声与钻芯取样的泵送混凝土结构柱欠振内部质量研究  

The Research on Internal Quality of Pumped Concrete Structural Columns under Insufficient Vibration Conditions Based on Ultrasonic Detection and Core Sampling

在线阅读下载全文

作  者:黄圣铨 HUANG Shengquan

机构地区:[1]福建省建筑科学研究院有限责任公司、福建省绿色建筑技术重点实验室,福建福州350108

出  处:《福建建设科技》2024年第4期30-32,共3页Fujian Construction Science & Technology

摘  要:本研究旨在评估欠振对泵送混凝土结构柱内部质量的影响。采用超声检测和钻芯取样方法,对高流动性泵送混凝土在欠振条件下的密实性及其缺陷程度进行了综合评估。研究结果表明,欠振会导致混凝土表面缺陷增多和内部气孔增加,进而降低混凝土的密实性和强度。即便是泵送混凝土,适当的振捣也是确保其结构完整性和耐久性的关键。所得结论对于施工实践的优化和混凝土质量控制具有重要的理论和实践意义。The study aims to evaluate the impact of under-vibration on the internal quality of pumped concrete structural columns.Using ultrasonic testing and core sampling methods,a comprehensive assessment was conducted on the compactness and degree of defects of high-fluidity pumped concrete under under-vibration conditions.The results indicate that under-vibration leads to an increase in surface defects and internal voids in concrete,thereby reducing its compactness and strength.The study emphasizes that even for pumped concrete,appropriate vibration is key to ensuring its structural integrity and durability.The conclusions drawn have important theoretical and practical significance for the optimization of construction practices and the quality control of concrete.

关 键 词:泵送混凝土 结构柱 欠振 密实性 超声法 钻芯法 

分 类 号:TU37[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象