1 000 MW发电机转子振动大原因分析与处理措施  

Analysis of the Causes of Rotor Vibration of 1000 MW Generator and Treatment Measures

在线阅读下载全文

作  者:周志凯 ZHOU Zhi-kai(Guangdong Electric Power Development Co.,Ltd.,Guangzhou,Guangdong 510000)

机构地区:[1]广东电力开发有限公司,广东广州510000

出  处:《江西电力职业技术学院学报》2024年第3期13-15,共3页Journal of Jiangxi Vocational and Technical College of Electricity

摘  要:针对某电厂1 000 MW发电机组转子振动大的现象,从该型号转子结构的特点出发,发现转子振动呈增大的趋势,着重描述了抽出转子和返厂检修发现的不正常情况,并进一步分析原因,提出处理措施,处理后转子运行良好,振动情况满足规程要求。In view of the phenomenon of large rotor vibration of 1000 MW generator set in a power plant,starting from the characteristics of the rotor structure of this model,it is found that the rotor vibration is increasing,and the abnormal situation found in the extraction of the rotor and the return to the factory for maintenance is emphatically described,and the causes are further analyzed,and the treatment measures are proposed,and the rotor runs well after treatment,and the vibration meets the requirements of the regulations.

关 键 词:发电机转子 振动增大 阻尼条风孔错位 阻尼条拱翘变形 

分 类 号:TV738[水利工程—水利水电工程]

 