法国石化装置4 Hz绝缘监察45年运行的调查报告  

Report on 45 Years of Operation of 4 Hz Insulation Measuring in Petrochemical Plants Imported from France

在线阅读下载全文

作  者:盖生 刘宏伟 赫胜男 GAI Sheng;LIU Hongwei;HE Shengnan(Old Science and Technology Association of Liaoyang Petrochemical Company,Liaoyang 111003,China;Liaoyang Petrochemical Branch,Liaoyang 111003,China)

机构地区:[1]辽阳石化老科协,辽宁辽阳111003 [2]辽阳石化分公司,辽宁辽阳111003

出  处:《电工技术》2024年第11期147-149,共3页Electric Engineering

摘  要:介绍法国石化装置供电用电规模、区域及生产环境,重点阐述了法国低压配电系统接线方式和接地制式,380 V小电流接地系统(IT制)架构、4 Hz绝缘监察。根据运行45年的实际案例证明欧洲4 Hz正弦交流用来测量带电运行的电动机绝缘电阻是一项有效技术,有必要设立专项加以研究,实现国产化、产业化和标准化。This paper reports power supply scale,region and production environment of the petrochemical plant imported from France.The wiring and grounding system,380 V small current grounding system(IT system)architecture and 4 Hz insulation measuring of French are outlined.According to the actual case of 45 years of operation the European 4 Hz insulation supervision for live motors is a beneficial technology and it is necessary to set up a special project and upgrade,and achieve localization,industrialization and standardization.

关 键 词:石化环境 低压配电 IT制 4 Hz绝缘监察 

分 类 号:TM21[一般工业技术—材料科学与工程]

 