一种电梯层门锁安全回路检测方法探讨  

Discussion on a Detection Method of Safety Circuit of Elevator Door Lock

在线阅读下载全文

作  者:张勇[1] 惠晓荣 王以亭 蔡祖明[1] 邢琬舒 Zhang Yong;Hui Xiaorong;Wang Yiting;Cai Zuming;Xing Wanshu(Hainan Institute of Boiler Pressure Vessel and Special Equipment Inspection,Haikou 570203)

机构地区:[1]海南省锅炉压力容器与特种设备检验所,海口570203

出  处:《中国特种设备安全》2024年第7期62-66,96,共6页China Special Equipment Safety

摘  要:针对传统方法对电梯进行短接检测时,存在短接线忘记拆除造成开门走梯的风险,本文提出一种新的检测方法,在不改变原有电气接线的同时,在机房控制柜处采集开门时门锁回路和抱闸回路的电压值,即可实现对每层门锁状态进行检测,进而对电梯是否存在短路故障做出判断。最后根据其原理设计了一款门锁检测装置,并通过实际测试验证了新检测方法的可行性和准确性。A new detection method is proposed in this paper to solve the risk that short wiring may be forgotten to remove when traditional detection methods are used to short-connect elevators,which can detect the status of door locks on each floor by collecting voltage values of the door lock circuit and the contracting brake circuit at the control cabinet of the computer room without changing the original electrical wiring.Then make a judgment on whether there is a short circuit fault in the elevator.Finally,a door lock detection device is designed according to the principle,and the feasibility and accuracy of the new detection method are verified by practical tests.

关 键 词:门锁回路 抱闸回路 检测方法 短路故障 检测装置 

分 类 号:X941[环境科学与工程—安全科学]

 