检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:鲍猛 张磬瀚 郑继红[1,2] 韦晓孝 万新军[1,2] 申桐 金旭东 BAO Meng;ZHANG Qinhan;ZHENG Jihong;WEI Xiaoxiao;WAN Xinjun;SHEN Tong;JING Xudong(School of Optical-Electrical and Computer Engineering,University of Shanghai for Science and Technology,Shanghai 200093,China;Shanghai Key Lab of Modern Optical System,University of Shanghai for Science and Technology,Shanghai 200093,China)
机构地区:[1]上海理工大学光电信息与计算机工程学院,上海200093 [2]上海理工大学上海市现代光学系统重点实验室,上海200093
出 处:《光学技术》2024年第4期411-418,共8页Optical Technique
基 金:上海市优秀学术/技术带头人计划(22XD1401000)。
摘 要:大像面荧光显微成像系统可以对大尺寸dPCR生物基因芯片进行一次性成像,但其景深(DOF)较小,限制了系统的物方检测深度。文章采用波前编码技术在不降低分辨率的前提下,有效扩展了大像面荧光显微成像系统的景深,为后续高通量多层堆叠式dPCR生物芯片实现一次性成像提供了技术支持。但考虑到显微成像系统正向设计仿真时不适合直接进行景深延拓分析,故对其倒置翻转后在像方(原物方)分析焦深延拓范围(即景深)。为确定最优的相位板参数值,编写遗传算法与ZEMAX的API接口链接,以动态交互的方式对相位板调制系数进行优化、筛选、定值。在大像面荧光显微成像系统孔径光阑前的平行光路处添加特定系数的相位板,对光学系统的波前相位进行调制,使得在焦点附近一段范围内产生成像一致的中间模糊像。采用维纳滤波对中间模糊像进行复原,由模拟的结果可见,在传统光学系统的±10倍景深内,编码复原图像具有较高的分辨率(达到6.5μm),能够实现系统的景深延拓。装配相位板的大像面荧光显微成像实际系统,其延拓倍数在±7倍景深范围内有较好的图像复原分辨率(6.5μm)。The large image area fluorescence microscopy imaging system can perform one-time imaging of large-size dPCR biological gene chips,but its depth of field(DOF,Depth of field)is small,which limits the object detection depth of the system.The wavefront coding technique is used to effectively expand the depth of field of the large image area fluorescence microscopy imaging system without reducing the resolution,which provides technical support for the subsequent one-time imaging of high-throughput multilayer stacked dPCR chips.However,considering that the forward design and simulation of the microscopic imaging system is not suitable for direct depth of field extension analysis,so it is inverted and flipped to analyze the focus depth extension range(i.e.,depth of field)on the image side(original object side).In order to determine the optimal phase plate parameter values,agenetic algorithm was written to link with ZEMAX's API interface,and the phase plate modulation coefficients were optimized,screened,and set in a dynamic interactive manner.A phase plate with a specific coefficient is added to the parallel light path in front of the aperture diaphragm of the large image area fluorescence microscopy imaging system to modulate the wavefront phase of the optical system,so that a consistent intermediate blurred image is produced within a range near the focus.The Wiener filter is used to restore the intermediate fuzzy image,and the simulation results show that the encoded image has a high resolution(up to 6.5μm)within the range of±10times depth of field of the traditional optical system,which can realize the depth of field extension of the system.The actual large image area fluorescence microscopy imaging system equipped with a phase plate has a good image restoration resolution(6.5μm)within the range of±7times the depth of field.
关 键 词:生物光学 波前编码 数字PCR 光学设计 荧光显微镜 图像处理
分 类 号:TP394.1[自动化与计算机技术—计算机应用技术] TH691.9[自动化与计算机技术—计算机科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.188.73.229