作 者:胡习兵 范周军 孙槐璟 周莹 HU Xibing;FAN Zhoujun;SUN Huaijing;ZHOU Ying(College of Civil Engineering,Central South University of Forestry and Technology,Changsha 410004,China;China Railway Urban Construction Group Corporation Limited,Changsha 411100,China)
机构地区:[1]中南林业科技大学土木工程学院,长沙410004 [2]中铁城建集团有限公司,长沙411100
出 处:《工业建筑》2024年第7期78-84,共7页Industrial Construction
基 金:湖南省自然科学基金面上项目(2020JJ4943)。
摘 要:为研究型钢连接装配式混凝土(PC)梁柱节点的抗震性能,采用通用有限元分析软件对型钢连接PC梁柱节点的滞回曲线和骨架曲线等抗震性能指标进行了分析。通过对比分析以及改变节点参数,探讨了柱顶轴压比、钢材强度等参数对节点抗震性能的影响。采用叠加法和曲线拟合法,提出了型钢连接PC梁柱节点总耗能简化计算式,并与多篇文献研究结果进行了对比,验证了算式的可靠性。研究结果表明:型钢连接PC梁柱节点抗震性能好,节点的混凝土强度、钢材强度、型钢厚度和梁柱截面高度均对节点抗震性能影响明显,节点总耗能的简化计算式具有较高的计算精度,可用于型钢连接PC梁柱节点及现浇钢筋混凝土节点的总耗能计算分析。In order to study the seismic performance of PC beam-column joints connected with section steel,the general finite element analysis software was used to analyze the seismic performance indexes such as hysteretic curves and skeleton curves of PC beam-column joints connected with section steel.Through comparative analysis and changes of joint parameters,the influence of axial compression ratio of column top and steel strength on seismic performance of joints was discussed.By using the superposition method and curve fitting method,a simplified formula for calculating the total energy consumption of PC beam-column joints connected with section steel was proposed,and the reliability of the formula was verified by calculat-ing with the results of several literature.The research results showed that the seismic performance of PC beam-column joints connected with section steel was good,the concrete strength,steel strength,section steel thickness and beam column section height of the joints had obvious influence on the seismic perform-ance of the joints,and the simplified calculation formula of the total energy consumption of the joints had high calculation accuracy,which can be used for the calculation and analysis of the total energy consump-tion of PC beam-column joints connected with section steel and cast-in-place reinforced concrete joints.
关 键 词:型钢连接装配式混凝土梁柱节点 抗震性能 有限元分析 总耗能
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.70