WS 582-2017《X、γ射线立体定向放射治疗系统质量控制检测规范》在江苏省跟踪评价结果分析  

Analysis on the tracking evaluation of WS 582-2017 Specifications for Testing of Quality Control in X and γ Ray Stereotactic Radiotherapy System in Jiangsu Province

在线阅读下载全文

作  者:曹兴江[1] 陈维[1] 范向勇[1] 王进[1] CAO Xingjiang;CHEN Wei;FAN Xiangyong;WANG Jin(Jiangsu Provincial Center for Disease Control and Prevention,Nanjing,Jiangsu 210000,China)

机构地区:[1]江苏省疾病预防控制中心,江苏南京210000

出  处:《中国职业医学》2024年第3期345-349,共5页China Occupational Medicine

基  金:国家卫生健康委法规司2023年度第一批卫生健康标准项目;江苏省医学重点学科(ZDXK202249)。

摘  要:目的训调查WS 582-2017《X、γ射线立体定向放射治疗系统质量控制检测规范》(以下简称“WS 582-2017”)在江苏省的贯彻执行情况和标准使用过程中遇到的问题,评价标准的科学性、合理性、适用性与可操作性。方法采用判断抽样方法,选择江苏省内54家医疗机构、放射卫生技术服务机构和卫生监督机构中122名涉及WS 582-2017使用的专业人员为研究对象,针对标准实施情况、技术内容、实施效果、对标准及标准工作的意见和建议等方面进行调查。结果研究对象对WS 5822017知晓率为76.2%,参加培训率为62.4%。93名知晓WS 582-2017人员中,92.5%的人员认为该标准科学严谨,73.1%的人员认为该标准可操作性强,96.8%的人员认为该标准与相关法规标准协调一致,87.1%的人员认为该标准对促进放射治疗放射防护最优化发挥了重要作用,89.2%的人员认为该标准对规范放射治疗设备质量控制检测工作发挥的作用明显,86.0%的人员认为该标准对提高相关技术人员的专业能力发挥的作用明显。该标准在江苏省的跟踪评估得分为81.9分。结论WS 582-2017在江苏省的总体实施情况好,技术内容的科学性和可操作性好,实施效果显著。但标准部分内容需要进一步完善;且需加强标准培训,以提高标准知晓率。Objective To investigate the implementation status and problem of WS 582-2017 Specifications for Testing of Quality Control in X and γ Ray Stereotactic Radiotherapy System(hereinafter refer to as "WS 582-2017") in Jiangsu Province since it was published, and evaluate the scientific, rational, applicable, and operational aspects of the standard. Methods A total of 122 professionals from 54 medical institutions, radiation health technical service institutions, and health supervision institutions in Jiangsu Province who were involved in the use of WS 582-2017 were selected as the research subjects using a judgmental sampling method. A survey was conducted on the implementation of the standard, technical content, implementation effects, opinions and suggestions on the standard and implementation work. Results The WS 582-2017 awareness rate was 76.2%, and the training participation rate was 62.4%. Among the 93 individuals who were aware of WS 582-2017, 92.5%believed that the standard was scientifically rigorous, 73.1% believed that the standard was highly operational, 96.8% believed that the standard was consistent with relevant regulations and standards, 87.1% believed that the standard played an important role in promoting the optimization of radiation protection in radiotherapy, 89.2% believed that the standard played an important role in standardizing the quality control inspection of radiotherapy equipment, and 86.0% believed that the standard played an important role in improving the professional competence of relevant technical personnel. The tracking evaluation score of the standard in Jiangsu Province was 81.9 points. Conclusion The overall implementation of WS 582-2017 in Jiangsu Province is good, with good scientific and operational technical content and great implementation effects. But the content of the standard needs to be further improved, and training needs to be strengthened to increase the awareness of the standard.

关 键 词:X、γ射线立体定向放射治疗系统 质量控制 标准跟踪 问卷调查 

分 类 号:R141[医药卫生—公共卫生与预防医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象