一起典型软启动水泵电机缺相故障分析  

Analysis of A Typical Open-Phase Fault of Soft Start Pump Motor

在线阅读下载全文

作  者:刘积慧 刘东芸 LIU Jihui;LIU Dongyun(Power Plant of Hongxing Co.,Ltd.,Jiuquan Iron and Steel Group;Gansu Iron and Steel Vocational Technical College,Jiayuguan,Gansu 735100,China)

机构地区:[1]酒钢宏兴股份公司动力厂 [2]甘肃钢铁职业技术学院,甘肃嘉峪关735100

出  处:《冶金动力》2024年第4期1-3,共3页Metallurgical Power

摘  要:缺相长期运行会导致电机烧损,影响企业的正常生产。电机运行过程中出现的发热、振动、运行电流升高、工艺参数变化等现象,均有可能是电机缺相引发的。造成电机缺相的主要原因是软启动器参数设定不合理或项目设计不严谨。通过对现场一起电机发热故障的分析,发现该型号早期的软启动器存在设计缺陷,无B相缺相保护,因此需要增加二次控制保护回路来完善电机的缺相保护功能,保障生产的安全稳定运行。Prolonged operation under open-phase fault will lead to motor burnout and affect the normal production of the enterprise.The phenomena such as heating,vibration,in⁃creased operating current,and changes in process parameters that occur during the operation of the motor may be triggered by open-phase fault of the motor.The main reason for the open-phase fault is the irrationality parameter settings of the soft starter or the lack of rigor in the project design.By analyzing a motor heating fault on site,it was found that the early soft starter of this model has design defects that there is no open-phase protection for B-phase,so it is necessary to increase the secondary control protection circuit to improve the motor's open-phase protection function,so as to ensure the safe and stable operation of production.

关 键 词:水泵电机 软启动器 缺相 

分 类 号:TM307[电气工程—电机]

 