出  处:《煤气与热力》2024年第7期7-9,共3页Gas & Heat

摘  要:结合工程实例,对住宅小区热源(区域燃煤锅炉房、空气源热泵)能耗及经济性进行分析。由经济性分析可知,燃煤锅炉房方案、空气源热泵方案的费用年值接近。与区域燃煤锅炉房相比,热泵机组供暖期能耗减少38.15%。因此,热源选取空气源热泵。Combined with an engineering example,the energy consumption and economy of the heat sources(district coal-fired boiler room and air source heat pump)in residential communities are analyzed.According to economic analysis,the annual costs of coal-fired boiler room scheme and air source heat pump scheme are close.Compared with district coal-fired boiler rooms,the energy consumption of heat pump units during the heating period is reduced by 38.15%.Therefore,an air source heat pump is selected as the heat source.