微波消解-石墨炉原子吸收光谱法测定硫化胶中的铅含量  

Determination of Lead Content in Vulcanizate by Microwave Digestion-Graphite Furnace Atomic Absorption Spectroscopy

在线阅读下载全文

作  者:程凡圣 孙世悦 徐旗 付友健 李崇兵 CHENG Fansheng;SUN Shiyue;XU Qi;FU Youjian;LI Chongbing(PRINX Chengshan(Shandong)Tire Co.,Ltd,Rongcheng 264300,China)

机构地区:[1]浦林成山(山东)轮胎有限公司,山东荣成264300

出  处:《橡胶科技》2024年第8期471-473,共3页Rubber Science and Technology

摘  要:建立微波消解-石墨炉原子吸收光谱法测定硫化胶中铅含量的方法。样品直接用微波高温快速消解,消解液稀释处理后采用石墨炉原子吸收光谱法测定铅含量。结果表明:在铅质量浓度为0~10.0μg·L^(-1)范围内,标准曲线线性关系良好,相关因数为0.9998;硫化胶中铅含量检出限为0.13μg·g^(-1),加标回收率为93.12%~101.25%,6次平行测试相对标准偏差为3.34%。该方法简便、快速,基体干扰少,测试结果准确。A method for determining lead content in vulcanizates was established using microwave digestion-graphite furnace atomic absorption spectroscopy.The sample was directly digested by microwave at high temperature,and the lead content was determined by graphite furnace atomic absorption spectroscopy after dilution of the digestion solution.The results indicated that at lead mass concentrations ranging from 0 to 10.0μg·L^(-1),the standard curve had a good linearity,with a correlation coefficient of 0.9998.The detection limit for lead content in vulcanizate was 0.13μg·g^(-1),and the spiked recovery rate ranged from 93.12%to 101.25%,with a relative standard deviation of 3.34%for six parallel determinations.This method was simple and fast,with minimal matrix interference and accurate test results.

关 键 词:硫化胶 铅含量 微波消解 石墨炉原子吸收光谱 

分 类 号:TQ330.72[化学工程—橡胶工业]

 