含有非变换凝液汽提系统的腐蚀分析与改进  

STUDY ON CORROSION AND IMPROVEMENT OF CONDENSATE STRIPPING SYSTEM WITH NON-CO SHIFT CONDENSATE

在线阅读下载全文

作  者:闻靖 Wen Jing(SINOPEC Ningbo Engineering Co.,Ltd.,Ningbo 315103)

机构地区:[1]中石化宁波工程有限公司,浙江宁波315103

出  处:《大氮肥》2024年第4期268-273,共6页Large Scale Nitrogenous Fertilizer Industry

摘  要:介绍含有非变换凝液汽提系统的腐蚀情况,针对腐蚀机理,采用分段汽提加碱中和、控制汽提塔塔顶冷凝器出口酸性气温度并加水洗氨、升级关键设备材质等手段,保证装置安全稳定的长周期运行。This paper introduced the corrosion situation of condensate stripping system with non-CO shift condensate.Based on the corrosion mechanism,measures such as segmented stripping and alkali neutralization,controlling the temperature of acid gas at the outlet of the stripping tower condenser and adding water for ammonia washing,upgrading key equipment materials,etc.were adopted to ensure the safe and stable long-term operation of the device.

关 键 词:一氧化碳变换 非变换流程 汽提系统 腐蚀 

分 类 号:TQ545[化学工程—煤化学工程] TQ050.9

 