作 者:张勇 Zhang Yong(Beijing Institute of Architectural Design Co.,Ltd,Beijing 100045,China)
机构地区:[1]北京市建筑设计研究院股份有限公司,北京100045
出 处:《智能建筑电气技术》2024年第4期53-58,共6页Electrical Technology of Intelligent Buildings
摘 要:本文重点梳理分析了ATSE自动转换开关、STS静态转换开关、SSTS固态转换开关与0.4kV母联的关系,明确了转换装置的动作时间和在配电系统中的作用。通过介绍PLC可编程双电源转换控制器,并结合具体工程案例分析0.4kV合环应用条件,使供配电系统功能更为完善,实现电源系统检修或故障恢复中的不断电操作。This article focuses on sorting and analyzing the relationship between ATSE automatic transfer switch,STS static transfer switch,SSTS solid-state transfer switch and 0.4kV busbar,clarifying the action time of the transfer device and its role in the distribution system.By introducing the PLC programmable dual power conversion controller and analyzing the application conditions of 0.4kV loop closure with specific engineering cases,the functions of the power supply and distribution system are improved,and uninterrupted power operation is achieved during power system maintenance or fault recovery.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7