动态心电图联合24h动态血压监测对原发性高血压患者心肌缺血的诊断价值  

The diagnostic value of Holter electrocardiogram combined with 24-h ambulatory BP monitoring for myocardial ischemia in patients with essential hypertension

在线阅读下载全文

作  者:陈杰伟 Chen Jiewei(Affiliated Hospital of Jiangnan University,Wuxi,Jiangsu 214000,China)

机构地区:[1]江南大学附属医院,江苏无锡214000

出  处:《首都食品与医药》2024年第16期24-26,共3页Capital Food Medicine

摘  要:目的探究在原发性高血压患者心肌缺血诊断中采用动态心电图联合24h动态血压监测的价值.方法回顾性分析2022年1月-2023年12月500例原发性高血压患者心肌缺血临床资料,均对其进行常规心电图联合24h动态血压监测(设为对照组),动态心电图联合24h动态血压监测(设为观察组),以冠状动脉造影作为金标准,分析诊断价值.结果金标准、观察组、对照组确诊真阳性依次为254例、234例、169例.观察组对各级别原发性高血压患者心肌缺血的检出率较高(P<0.05).观察组灵敏度、特异度、阳性以及阴性预测值、诊断符合率较高(P<0.05).结论对原发性高血压患者心肌缺血诊断时,采用动态心电图联合24h动态血压监测,诊断价值较高.Objective To investigate the value of using dynamic electrocardiogram combined with 24-h ambulatory blood pressure monitoring in the diagnosis of myocardial ischemia in patients with essential hypertension.Methods The clinical data of 500 cases of myocardial ischemia in patients with essential hypertension from January 2022 to December 2023 were retrospectively analyzed,and they were all subjected to conventional electrocardiography combined with 24-h ambulatory blood pressure monitoring(set up as the control group),and dynamic electrocardiography combined with 24-h ambulatory blood pressure monitoring(set up as the observation group),and the diagnostic value of the diagnosis was analyzed by using coronary arteriography as the gold standard.Results The confirmed true-positive diagnosis of the gold standard,observation group,and control group was 254 cases,234 cases,and 169 cases in that order.The detection rate of myocardial ischemia in patients with primary hypertension at all levels was higher in the observation group(P<0.05).The sensitivity,specificity,positive as well as negative predictive value,and diagnostic compliance rate were higher in the observation group(P<0.05).Conclusion The diagnosis of myocardial ischemia in patients with essential hypertension is of high diagnostic value with the use of ambulatory electrocardiography combined with 24-h ambulatory blood pressure monitoring.

关 键 词:动态心电图 24H动态血压监测 原发性高血压心肌缺血 诊断价值 

分 类 号:R541.4[医药卫生—心血管疾病]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象