主线管道与支线管道间绝缘装置对管道阴极保护影响的探索  

Discussion on the Influence of Insulation between Pipeline and Branch Pipeline on the Overall Cathodic Protection of Pipeline

在线阅读下载全文

作  者:赵世豪 段玉沙 尹安 刘晓龙 孙长富 ZHAO Shi-hao;DUAN Yu-sha;YIN An;LIU Xiao-long;SUN Chang-fu(Qingdao NCS Testing&Corrosion Protection Technology Co.,Ltd.Qingdao 266071,China)

机构地区:[1]青岛钢研纳克检测防护技术有限公司,山东青岛266071

出  处:《全面腐蚀控制》2024年第7期170-173,共4页Total Corrosion Control

摘  要:目前管道支线越来越多,而部分管道支线铺设时并未设置绝缘装置,这造成了管道阴极保达不到标准要求,本文通过馈电实验及PCM漏电率法验证了支线管道电流流失情况,并在整改后管道阴极保护效果有明显改善,达到标准要求。At present,there are more and more pipeline branches,and some pipeline branches are laid without insulation devices,which results in the cathodic protection of pipelines not meeting the standard requirements.This article verifies the current loss situation of branch pipelines through feeding experiments and PCM leakage rate method,After rectification,the cathodic protection effect of the pipeline has significantly improved,meeting the standard requirements.

关 键 词:绝缘 馈电实验 PCM漏电率法 

分 类 号:TG179[金属学及工艺—金属表面处理]

 